Direct liquid chromatography with photodiode and fluorescence detection for simultaneous quantification of gonadotropin-releasing hormone (GnRH), its complex with Cu2+, and catabolites.
Autorzy
Rok wydania
2009
Czasopismo
Numer woluminu
83
Strony
383-390
Kolekcja
Język
Angielski
Typ publikacji
Artykuł
Gonadotropin-releasing hormone (GnRH) and its complex with Cu2+(Cu-GnRH) were separated on a Nova Pak C18 column (4 m, 150 3.9 mm I.D., Wa ters). Analyses of underivatized GnRH and Cu-GnRH were per formed by a gradient elution program (HPLC method I), UV detection at 280 nm and fluorescence detection (gammexcitation = 280 nm/gammaemis sion = 360 nm). The mobile phases used were: acetonitrile with 0.08% trichloroacetic acid (w/w) and water with 0.1% trichloroacetic acid (w/w). Elutions were carried out in a binary gradient mode with a flow-rate of 1 mL/min and column temperature of 28°C. The proposed gradient elution program with UV and fluorescence detection allowed satisfactory fraction ation of GnRH (at 31.5 plus minus 0.2 min) from Cu-GnRH (at 30.3 plus-minus 0.2 min) and endogenous species present in samples of cytosol and subcellular organelles from the hypothalamus. The proposed reversed-phase HPLC method I with fluorescence detection provides a more sensitive analytical tool for routine and simultaneous quantification of GnRH, Cu-GnRH and their enzymatic degradation products (catabolites) in all biological samples as compared with HPLC method I with UV detection. To avoid problems due to overlap ping peaks corresponding to GnRH, Cu-GnRH, and the respective enzymatic degradation products in samples of cytosol and subcellular organelles from the hypothalamus, we propose a very shallow binary gradient elution program (method I). The separation efficiency of GnRH and Cu-GnRH peaks in standards and biological samples was assessed based on purity analysis of UV spectra (250-300 nm) and on the values of ratios of the fluorescence response to UV response at 280 nm. Our second reversed-phase liquid chromatographic method (HPLC method II) with pre-column derivatization of aminoacids in catabolites of GnRH and Cu-GnRH enabled investigations of the degradation pattern as well as of the yield of enzymatic degradation of GnRH and its Complex with Cu2+ in pituitary cytosol and sub-cellular organelles.
Słowa kluczowe
gonadotropin-releasing hormone (GnRH), Cu-GnRH, GnRH and Cu-GnRH catabolites, reversed-phase HPLC, UV detection, fluorescence detection
Adres publiczny
http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.baztech-article-BUJ5-0024-0080
Podobne publikacje
Impact of the Cu(II) ions on the chemical and biological properties of goserelin : coordination pattern, DNA degradation, oxidative reactivity and in vitro cytotoxicity.
Walencik Paulina K., Stokowa-Sołtys Kamila, Wieczorek Robert, Komarnicka Urszula K., Kyzioł Agnieszka, Jeżowska-Bojczuk Małgorzata
Further structural analysis of GnRH complexes with metal ions.
Nakamura K., Kodaka M., El-Mehasseb I. M., Gajewska A., Okuno H., Ochwanowska E., Witek B., Kozłowski Henryk, Kochman K.
Structural analysis and sheep pituitary receptor binding of GnRH and its complexes with metal ions.
D'Amelio N., Gaggelli Elena, Gajewska A., Kochman H., Kochman K., Kozłowski Henryk, Latajka Zdzisław, Młynarz Piotr, Panek Jarosław, Valensin Gianni